听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览CLINICAL CHEMISTRY期刊下所有文献
  • Free triiodothyronine and free thyroxin in sera of pregnant women and subjects with congenitally increased or decreased thyroxin-binding globulin.

    abstract::Concentrations of free thyroxin (T4) and free triiodothyronine (T3) were measured in sera from pregnant women, in subjects with congenitally increased or decreased thyroxin-binding globulin (TBG), and in euthyroid controls. Measured free hormone concentrations were compared with calculated values for free hormone deri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Franklyn JA,Sheppard MC,Ramsden DB,Hoffenberg R

    更新日期:1983-08-01 00:00:00

  • Gas-chromatographic determination of cholesterol sulfate in plasma and erythrocytes, for the diagnosis of recessive X-linked ichthyosis.

    abstract::We describe a rapid method for determining cholesterol sulfate in plasma and erythrocytes. After its single-step isolation by means of anion-exchange chromatography cholesterol sulfate is hydrolyzed, trimethylsilylated, and determined by gas chromatography with flame ionization detection. 5 beta-Cholestan-3 alpha-ol s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Muskiet FA,Jansen G,Wolthers BG,Marinkovic-Ilsen A,van Voorst Vader PC

    更新日期:1983-07-01 00:00:00

  • Specific micro-radioimmunoassay for prednisolone in serum.

    abstract::Use of an 125I radioimmunoassay involving antiserum coupled to magnetizable cellulose, after prednisolone-21-phosphate interference is removed by dichloromethane extraction at pH 7.4 and endogenous glucocorticoid interference is removed by selective chemical derivatization with Girard's Reagent T [(carboxymethyl)trime...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Olivesi A,Smith DS,White GW,Pourfarzaneh M

    更新日期:1983-07-01 00:00:00

  • Sample preparation with ion-exchange resin before liquid-chromatographic determination of plasma catecholamines.

    abstract::Estimation of plasma catecholamine concentrations by "high-performance" liquid chromatography, although increasingly used, still presents difficulties. We describe a method for clean-up of plasma samples on cation-exchange resin before they are extracted with alumina. This procedure eliminates many of the interfering ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frayn KN,Maycock PF

    更新日期:1983-07-01 00:00:00

  • Kinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.

    abstract::We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-star...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: de Rijke D,Kreutzer HJ

    更新日期:1983-06-01 00:00:00

  • Reflectance digital matrix photometry.

    abstract::We have designed and constructed a digital matrix photometer for quantitative measurement of reflected light of small chromophoric areas or colored spots. The areas are divided conceptually into small subunits in which the reflected light is measured. This is done through stepwise scanning with a photodiode array. The...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-06-01 00:00:00

  • Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry.

    abstract::This method for determining aluminum in human serum involves electrothermal atomic absorption spectrophotometry. A longer drying time allows less pre-dilution of the sample, and the method also includes a flush cycle after atomization. Standard-addition methodology is used to eliminate matrix effects and the need for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bertholf RL,Brown S,Renoe BW,Wills MR,Savory J

    更新日期:1983-06-01 00:00:00

  • Capillary gas-chromatographic determination of urinary homovanillic acid and vanillylmandelic acid.

    abstract::This relatively simple, rapid method for quantification of homovanillic acid (HVA) and vanillylmandelic acid (VMA) involves solvent extraction and capillary gas chromatography. With use of this extraction method, the overall analytical recovery from an aqueous solution is 92.5% for HVA and 79.2% for VMA. 3,4-Dihydroxy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tuchman M,Crippin PJ,Krivit W

    更新日期:1983-05-01 00:00:00

  • Ferritin concentrations in plasma from capillary (finger prick) blood and venous blood compared.

    abstract::Investigating the feasibility and validity of determining plasma ferritin concentration in blood obtained by finger prick, we studied 29 adults (ages 21-49 years) and 35 children (ages 14-66 months). Blood was sampled simultaneously in the same subject from both the antecubital vein (venous blood) and by finger pricki...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mejía LA,Viteri FE

    更新日期:1983-05-01 00:00:00

  • Total bone and liver alkaline phosphatases in plasma: biological variations and reference limits.

    abstract::We have studied factors affecting biological variation in total plasma alkaline phosphatase in a population of 32 329 apparently healthy subjects four years old or older. Quantification of the bone and liver isoenzymes after thermal denaturation made it possible to specify the contributions of each isoenzyme to variat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schiele F,Henny J,Hitz J,Petitclerc C,Gueguen R,Siest G

    更新日期:1983-04-01 00:00:00

  • Performance of the Hitachi 705 evaluated.

    abstract::We evaluated a new discrete analyzer, the Hitachi 705. The instrument can process sequentially as many as 19 different enzymes or other analytes, with a throughput of 180 tests per hour. We evaluated the spectrophotometer, the sample and reagent probes, and the performance for 11 assays: creatine kinase, aspartate ami...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Douville P,Forest JC

    更新日期:1983-04-01 00:00:00

  • "Sandwich" enzyme immunoassay for serum ferritin with polypropylene test tubes as the solid phase.

    abstract::A "sandwich" enzyme immunoassay for ferritin in human serum is described, in which horseradish peroxidase-labeled antibody and a very sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazolin-6-sulfonate), are used. The solid phase is polypropylene test tubes treated with glutaraldehyde; immunologic reactions are devel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Revenant MC

    更新日期:1983-04-01 00:00:00

  • Ultracentrifugation in swinging-bucket and fixed-angle rotors evaluated for isolation and determination of high-density lipoprotein subfractions HDL2 and HDL3.

    abstract::We evaluated the density-gradient ultracentrifugation method in a swinging-bucket rotor (Anal Biochem 111, 149-157, 1981) in a slightly modified version for isolation and determination of high-density lipoprotein (HDL) subfractions. We prestained the serum with Coomassie Brilliant Blue R, which did not change the hydr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Demacker PN,van Sommeren-Zondag DF,Stalenhoef AF,Stuyt PM,van't Laar A

    更新日期:1983-04-01 00:00:00

  • Improved measurement of acetylsalicylic acid esterase in serum.

    abstract::A fixed-time incubation method for measuring acetylsalicylic acid esterase was improved by using a higher concentration of the substrate, acetylsalicylic acid, and an activator, Ca2+. The enzymatic activity in serum was 25-fold that measured by earlier methods. Inhibition studies showed a pattern similar to that repor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sørensen S

    更新日期:1983-03-01 00:00:00

  • Radioimmunometric assay for a monoclonal antibody-defined tumor marker, CA 19-9.

    abstract::We describe a solid-phase radioimmunometric sandwich assay for a new tumor marker defined by a monoclonal antibody (19-9). This antibody reacts with a carbohydrate antigenic determinant (CA 19-9) found at low concentrations in sera from healthy individuals but frequently increased in sera from patients with adenocarci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Del Villano BC,Brennan S,Brock P,Bucher C,Liu V,McClure M,Rake B,Space S,Westrick B,Schoemaker H,Zurawski VR Jr

    更新日期:1983-03-01 00:00:00

  • Sensitivity and specificity of the hydrogen breath-analysis test for detecting malabsorption of physiological doses of lactose.

    abstract::We examined the changes in sensitivity and specificity that would occur with alterations in the sample-collection schedule and (or) cutoff criterion for the increase in hydrogen concentration in breath after administration of doses of lactose in the dietary range. In a breath-analysis test to classify individuals as l...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosado JL,Solomons NW

    更新日期:1983-03-01 00:00:00

  • Isoelectric focusing in agarose: classification of genetic variants of alpha 1-antitrypsin.

    abstract::Polyacrylamide has been the matrix of choice for isoelectric focusing owing to the virtual absence of electroendosmosis in this medium. Certain inherent limitations associated with polyacrylamide have prompted some investigators to use low-electroendosmosis agarose for isoelectric focusing, but with limited success th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buffone GJ,Stennis BJ,Schimbor CM

    更新日期:1983-02-01 00:00:00

  • A direct radioimmunoassay for aldosterone in plasma.

    abstract::This rapid radioimmunoassay for aldosterone is performed directly on 100 microL of unprocessed plasma, with 125I-labeled aldosterone as the labeled antigen. Our use of steroid-free plasma in preparing the standard curve resulted in an overestimate of aldosterone; this problem was overcome by adding to such plasma a mi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lun S,Espiner EA,Nicholls MG,Yandle TG

    更新日期:1983-02-01 00:00:00

  • Measurement of glycosylated hemoglobin on cellulose acetate membranes by mobile affinity electrophoresis.

    abstract::In this method for separating glycosylated from nonglycosylated hemoglobin in blood by electrophoresis on cellulose acetate membranes, we exploit the affinity of low-molecular-mass dextran sulfate for the nonglycosylated fraction, which increases the mobility of the latter relative to that of glycosylated hemoglobin. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ambler J,Janik B,Walker G

    更新日期:1983-02-01 00:00:00

  • Complexes of immunoglobulins A and G with aspartate aminotransferase isoenzymes in serum.

    abstract::We report the presence of complexes between aspartate aminotransferase (AST, EC 2.6.1.1) and immunoglobulin (Ig) in the serum of a patient suffering from lung cancer with metastasis to the liver. After fractionation of the serum by gel filtration, AST-Ig complexes (AST-IgA, AST-IgG) were demonstrated by counterimmunoe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nagamine M,Okochi K

    更新日期:1983-02-01 00:00:00

  • Fluorometric procedure for determining "lamellar body" phospholipids in the particulate fraction of amniotic fluid after filtration.

    abstract::A rapid (30-min) semiautomated continuous-flow procedure is described for use in assessing the phospholipids of the particulate ("lamellar body") fraction of human amniotic fluid. The method is based on measuring the difference in fluorescence of 1,6,-diphenyl-1,3,5-hexatriene added to amniotic fluid before and after ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Egberts J,Soederhuizen W,Gebhardt DO

    更新日期:1983-02-01 00:00:00

  • Further studies on danazol interference in testosterone radioimmunoassays.

    abstract::Investigating the interference of danazol in testosterone radioimmunoassays, we measured serum testosterone concentrations in the serum of women receiving danazol, with three testosterone radioimmunoassay kits. All of these showed positive interference by danazol or its metabolites (or both). Values for testosterone o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sharp AM,Fraser IS,Caterson ID

    更新日期:1983-01-01 00:00:00

  • Evolutionary changes in acute-phase proteins in alcoholic hepatocellular diseases.

    abstract::We studied the pattern of acute-phase proteins (orosomucoid, C-reactive protein, and haptoglobin) in hepatocellular deficiency due to chronic alcohol consumption, characterized by a decrease in serum transferrin concentration. We found that their patterns could vary independently of hepatocellular deficiency, but depe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Perier C,Chamson A,Engler R,Frey J

    更新日期:1983-01-01 00:00:00

  • Effect of protein on the determination of total bile acids in serum.

    abstract::We measured total serum bile acids on a fluorescence-light-scattering micro centrifugal analyzer by the direct enzymatic method with 3 alpha-hydroxysteroid dehydrogenase (EC 1.1.1.50) and with resazurin as a fluorogenic electron acceptor. We found that serum protein has an inhibitory effect on the measurement of bile ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hanson NQ,Freier EF

    更新日期:1983-01-01 00:00:00

  • Enzyme immunoassay of thyroxin-binding globulin.

    abstract::We describe a new double-antibody enzyme radioimmunoassay for thyroxin-binding globulin (TBG) in serum. A TBG-beta-D-galactosidase complex was prepared with m-maleimidobenzoyl N-hydroxysuccinimide ester. The mean analytical recovery of TBG added to serum was 99%, sample volume and TBG value were linearly related, and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miyai K,Ito M,Hata N

    更新日期:1982-12-01 00:00:00

  • Four methods for glucose assay compared for various glucose concentrations and under different clinical conditions.

    abstract::Glucose was measured by the ferricyanide, the Beckman glucose oxidase, and the hexokinase procedures in 228 plasma samples taken during standard oral glucose-tolerance tests in 17 normal subjects and in 21 chemical diabetics. The neocuproine method was also used to measure glucose concentration in 156 samples (78 befo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Giampietro O,Pilo A,Buzzigoli G,Boni C,Navalesi R

    更新日期:1982-12-01 00:00:00

  • Evaluation of some critical factors affecting determination of aluminum in blood, plasma, or serum by electrothermal atomic absorption spectroscopy.

    abstract::A digestion procedure involving nitric acid is described for determination of aluminum in blood, serum, and plasma by graphite-furnace atomic absorption spectroscopy. Contamination was not a severe problem if all operations were performed in a dust-free atmosphere. Conditions for such determination of aluminum in bloo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frech W,Cedergren A,Cederberg C,Vessman J

    更新日期:1982-11-01 00:00:00

  • Two automated methods for plasma antithrombin III compared, and the clinical significance of the results.

    abstract::Antithrombin III (AT III) activity was determined with two different new chromogenic substances--Chromozym-TH (Tos-Gly-Arg-p-nitroanilide; Boehringer Mannheim) and alpha-N-carbobenzyl-oxy-L-lysine-thiobenzyl ester (Du Pont)--with both a discrete (aca) and a centrifugal analyzer (COBAS BIO). The correlation between the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Prellwitz W,Schmitt KF,Machner M,Schuster CJ,Weilemann L

    更新日期:1982-11-01 00:00:00

  • Evaluation and comparison of immunoinhibition and immunoprecipitation methods for differentiating MB and BB from macro forms of creatine kinase isoenzymes in patients and healthy individuals.

    abstract::We compared results for measurements of creatine kinase isoenzyme MB (CK-MB) by immunoinhibition vs immunoprecipitation, using sera from 53 normal healthy individuals, 55 patients with increased CK-MB associated with acute myocardial infarction, and 42 patients whose blood exhibited one or more abnormal forms of CK by...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu AH,Bowers GN Jr

    更新日期:1982-10-01 00:00:00

  • Evaluation of determination of glucose in urine with some commercially available dipsticks and tablets.

    abstract::Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dyna...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bandi ZL,Myers JL,Bee DE,James GP

    更新日期:1982-10-01 00:00:00

  • Five creatine kinase isoenzymes in serum of a patient with severe heart disease.

    abstract::Abnormal creatine kinase (CK) isoenzyme patterns were observed in the serum of a 64-year-old woman with severe heart disease. Agarose electrophoresis revealed the presence of all the usual CK isoenzymes (MM, MB, and BB) plus an extra band between MM and MB. Total serum CK activity was within the normal range. Within 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Csako G,Papadopoulos NM,Jett GK,McIntosh CL

    更新日期:1982-10-01 00:00:00

  • Interference in a chromogenic alpha-amylase assay caused by dye-labeled oligosaccharide-induced precipitation of lipoprotein.

    abstract::We examined the mechanism by which hypertriglyceridemia interferes with the Roche Diagnostics "Amylochrome" procedure for measurement of amylase in lactescent samples with normal and above-normal amylase activity. The serum blank recommended in the Amylochrome protocol to compensate for lactescence remains inappropria...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wickus GG,Dukerschein RO,Pierce JR,Davis KD

    更新日期:1982-10-01 00:00:00

  • Development of a multichannel electrochemical centrifugal analyzer.

    abstract::A new instrument has been developed that is similar in design and concept to the GeMSAEC centrifugal analyzer (Oak Ridge National Laboratory) except that electrochemical detection is used rather than optical detection. The present version has eight channels, each with its own detector. Problems of speed control and sa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cho HK,Lee YH,Couch RA,Jagadeesh JM,Olson CL

    更新日期:1982-09-01 00:00:00

  • Analytical problems facing the development of electrochemical transducers for in vivo drug monitoring: an overview.

    abstract::Even though significant progress has been made in the development of electrodes for the in vivo detection of catecholamines, oxygen, and various cations, there has been little research on the feasibility of continuously monitoring drugs in whole blood by electrochemical sensing devices. Electroanalytical problems asso...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pinkerton TC,Lawson BL

    更新日期:1982-09-01 00:00:00

  • Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

    abstract::Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kost GJ,Chow JL,Kenny M

    更新日期:1982-07-01 00:00:00

  • Comparison of calculated and measured free thyroid hormones in serum in health and in abnormal states.

    abstract::To evaluate a theoretical model for calculating free thyroid hormones, based on the law of mass action, we compared values for both calculated and measured free thyroxin and free triiodothyronine in a group of normal subjects. To determine whether the concentrations of circulating free hormones were also predictable f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fresco G,Curti G,Biggi A,Fontana B

    更新日期:1982-06-01 00:00:00

  • Clinical applications of protein determinations in biological fluids other than blood.

    abstract::Over the past decade, significant improvements in immunochemical and electrophoretic techniques have enabled collection of heretofore unavailable data on proteins in biological fluids, greatly increasing our understanding of protein physiology in the various body compartments and providing the foundation for clinical ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Killingsworth LM

    更新日期:1982-05-01 00:00:00

  • On the use and computation of likelihood ratios in clinical chemistry.

    abstract::The clinical relevance of likelihood ratios (L-values) for revising the physician's diagnostic probabilities has been recognized. However, the calculation of L-values, particularly in the case of quantitative or mixed quantitative-binary test results, raises problems that have not yet been addressed. Based on a very g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Albert A

    更新日期:1982-05-01 00:00:00

  • Diagnostic and prognostic value of laboratory tests assessed in a follow-up study of 200 patients with liver disease.

    abstract::Two hundred patients with liver disease were re-studied after six to eight years. The initial routine diagnosis (mainly based on morphological criteria) was confirmed in almost 80% of cases of chronic liver disease. In chronic active hepatitis, agreement was found in 86%. An alternative classification based on cluster...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Skrede S,Solberg HE,Ritland S,Blomhoff JP,Schrumpf E,Elgjo K,Gjone E

    更新日期:1982-05-01 00:00:00

  • Two-dimensional gel electrophoresis of serum specimens from patients with monoclonal gammopathies.

    abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tracy RP,Currie RM,Kyle RA,Young DS

    更新日期:1982-04-01 00:00:00

1213 条记录 24/31 页 « 12...21222324252627...3031 »